The Respironics Millennium is used for the M Series generators. These units are reconditioned, rebuilt and modified for torch use. With the correct maintenance, these units will give you years of Unlimited Oxygen. All our units come with a 3 year warranty. Items not covered under the warranty is abuse, lack of maintenance, shipping and out of USA sales. All the M series (M5, M10, M15 and M20) are single compressor units. The M series units all pull 5 amps and around 600 watts. Actual average power consumption is 460 watts. All are 110 volt and 60 hz.
All our units come with new filters that are located in the back behind the small square access door. When you recieve your unit, you should check to make sure that the filter is in the right position, which is standing upright in the compressor opening. Each filter should be checked monthly and replaced every 6 months or as needed. Other specs Include:
operating pressure: M5 is 5 to 7 psi, M10 is 10 psi, M15 is 15 psi 
and the M20 is 20 psi
operating temp: 55 to 95 degrees F and 15 to 32 degrees C
Storage and transport temp: 30 to 160 degrees F and 34 to 71 
degrees C.
Storage Humidity: Up to 95%
Altitude Operation: Up to 7500 Ft or 2285 Meters
Oxygen concentration: 92% plus or minus 4%
Volts 110 60 hz
Unboxed unit weigh is 49 pounds
NOTE: Operating the unit outside any of these peremeters may result in low oxygen percentage and even damage. Unlimited Oxygen does NOT have a refund policy. We may replace or repair any problem unit at our own discretion. We offer full tech support and 7 day phone response. We can usually troubleshoot most problems over the phone.
Other Instructions:
Upon recieveing your Unlimited Oxygen unit, remove it from the shipping carton. Give the unit a thourough visual inspection checking for cracks or other shipping damage. Open the filter access door and check the filter. If damage is noted, please notify Unlimited Oxygen. If no damage is noted, plug the unit into a wall outlet and turn it on. Listen for any strange noise. The unit should run quietly. A light breathing sound can be heard and is normal. The flow indicator ball should rise to a level and can be adjusted by turning the flow knob. Never run the flow above the prescribed flow rate. M5 is 5 lpm, M10 is 5 lpm, M15 is 8 lpm and the M20 is 10 lpm. Running the flow too high can cause the oxygen purity to drop to levels that wont run your torch.
Matching your torch to an Unlimited Oxygen Generator:
Minor burners = M5, M10 and M15
Mid-Range torch= 2 M15s, M20, Hurricane
Major Burners= Hurricane Combo (Hurricane and Booster), Psyclone Combo (Psyclone and Booster) Multable M15s or M20s